The user interface of the Brady IRX200 consists of six LED indicators:
- Power LED
- Link LED
- Ready LED
- Data LED
- Eroor LED
- 2 LED bars
LED | Mode | State | Indication |
Power | ALL MODES | Off | Device is not on. |
ALL MODES | Green, static | The device is powered on. | |
ALL MODES | Orange, static | The device is upgrading | |
Link | ALL MODES | Off | Off: All the communication interfaces are disabled. |
ALL MODES | Green, slow blinking | Ethernet/PROFINET link is up. | |
ALL MODES | Orange, blinking | Blinking according to received or transferred data | |
Ready | ALL MODES | Off | No set IP or the ethernet cable is not attached. Device is not on. |
NORMAL/ OPC UA | Green. slow blinking | IP set. | |
NORMAL/ OPC UA | Green, static | RFID service running while having an IP. | |
PROFINET | Green, static | Active PROFINET connection. | |
PROFINET | Green, fast blinking | Link is up, IP defined, not connected in PROFINET | |
Data | ALL MODES | Off | Device is not on. |
NORMAL/ OPC UA | The data LED can be controlled by the device’s system APIs. Indicates that the device has data for the PLC. | ||
PROFINET | Green, static | Device has outgoing data waiting to be read. | |
PROFINET | Red, static | Device outgoing buffer is full, PLC has not read incoming. | |
RF | ALL MODES | Off | The RFID module is not transmitting. |
ALL MODES | Green, static | The RFID module (NUR service) is transmitting. | |
ALL MODES | Yellow, static | High reflections at receiver. | |
ALL MODES | Blue, static | Access/write/read error | |
ALL MODES | Red, static | RFID hardware error. | |
Error | ALL MODES | Red, blinking | Critical internal error. |
LED bars | The LED bars can be controlled by the device’s system APIs. |
The placement of individual LEDs and the LED bars of the Brady IRX200 RF LED |