ELECTRICAL AND MECHANICAL SPECIFICATIONS
Supported standard | ISO 18000-63 (EPC Class 1 Gen2v2)
|
Frequency | ETSI 865.6–867.6 MHz or FCC/IC 902–928 MHz
|
Integrated antenna features
| Circular polarization with very low axial ratio
|
Maximum radiated RF power | 33dBm (2W) ERP / 3.3W EIRP
|
Max receiver sensitivity
| -87 dBm
|
Reading speed
| Reading speed
|
Reading speed
| 1 RP-TNC female with maximum conducted power 30dBm
|
CPU | Dual-core 64bit A53 with quad-core R5F co-CPUs
|
Operating system
| Hardened Linux
|
Memory
| 2GB RAM, 8GB Flash
|
Indicators | &pcs status LEDs, 2pcs high visibility LED bars |
LAN | Ethernet 10/100/1000mbit, Connector: M12 A-coded 8 pin |
USB | USB composite device (CDC/HID/RNDIS/ECM),Connector:M12 A-coded 8pin |
IO | 1 input and 1 output, 24V output for powering sensors
|
Operating power | 12W with maximum RF transmission power on, 4W in idle state, RF not transmitting
|
External power supply
| AC adapter: input 100–240 VAC, 1 A, 50-60 Hz / output 24 VDC, 1.25A, 30W / Power adapter for EU, UK or US Connector: M12 L-coded (FE connected)
|
Dimensions | H 200 mm W 200 mm L 28 mm
|
Weight
| 1.1 kg / 38.8 oz
|
Management interface | Via Web management UI and SSH for developers
|
Firmware update
| Via Web management UI and the RESTful service
|
IP addressing
| IPv4 DHCP (DCP in PNIO mode) or static IP
|
API support
| NUR API for RFID and RESTful service to access reader configurations, IRP API for PNIO
|
Security
| TSL v1.3
|
Industrial protocols
| OPC UA AutoID server support Profinet IO device CC-B with 1ms cycle time
|
Software development | Application can be written with modern programming languages. Internal RPC library for C++/Rust/Python/C#
|
Temperature
| Operating Storage -20 to +55 °C -4 to +131°F -20 to +60 °C -4 to +140 °F
|
Relative humidity
| 10 % to 95 % non-condensing
|
Mounting
| VESA 100 compatible
|
Environmental sealing
| IP67
|
Shock and vibration
| EN60068-2-27 / EN60068-2-6(4)
|
ESD
| Contacts Air discharge +/- 4kVdc +/- 8kVdc
|